Наш телефон: 8 921 751-66-99
       
English  Русский 
Каталог
Валюта:

Сортировать по: наименованию (возр | убыв), цене (возр | убыв), рейтингу (возр | убыв)

<< пред   1   ...  13   14   15   16   17   18   19   20   21   22   23    ...   46   след >>

COMPANDING CONVERSION MODULE Daughter card for the single T1 interface card (90-0093-05) or the single E1 interface card (90-0371-02). Provides for A law to Mu law conversion.
Доступно под заказ
CONTROL CARD
90-1726-02
CONTROL CARD
Доступно под заказ
CONTROL CARD 2
90-1995-01
CONTROL CARD 2
Доступно под заказ
CONTROL CARD 2 R4.3 clei The Control Card 2 implements the control complex functions for the node. The Control Card 2 provides two RS-232 ports node management (local and/or remote NMTI), and one Ethernet 10BaseT interface port for network management system access. One Control Card is required for a non-redundant control complex and two for control complex redundancy per 36170 system. Node management, alarm, and timing termination require a control card interconnect panel (CCIP). One CCIP serves both active and redundant control cards. There are two variants of CCIP for US Telco (90-2295-x1) and International (90-2295-x2) requirements. This card is delivered with R4.3 software. This assembly contains a Telcordia CLEI (Common Language Equipment Identifier) label.
Доступно под заказ
CONTROL CARD-2 W/ EPM R4.3 clei The Control Card 2 implements the control complex functions for the node. The Control Card 2 provides two RS-232 ports node management (local and/or remote NMTI), and one Ethernet 10BaseT interface port for network management system access. One Control Card is required for non-redundant control complex and two for control complex redundancy per 36170 system. Node management, alarm, and timing termination require a control card interconnect panel (CCIP). One CCIP serves both active and redundant control cards. There are two variants of CCIP for US Telco (90-2295-x1) and International (90-2295-x2) requirements. This card is delivered with R4.3 software, and with an enhanced Processor Module (ePM), and with a NAND-based 256MB memory card. Note that previous to this note, all control cards were shipped wih NOR-based memory cards. The software loadset required for this card is documented in Field Notice FN1867. This assembly contains a Telcordia CLEI (Common Language Equipment Identifier) label.
Доступно под заказ
CONTROL MODULE VR 6
Доступно под заказ
CPSS MODULE
90-1045-01
CPSS MODULE
Доступно под заказ
CTL CARD I/O PNL INTERNATIONAL The Control Card I/O Panel provides connectorization for both the active and standby Control Cards. The interfaces provided are: Ethernet 10BaseT, RS-232, and External clock inputs/outputs via BNC co nnectors (2meg).
Доступно под заказ
CTL CARD I/O PNL US TEL clei The Control Card I/O Panel provides connectorization for both the active and standby Control Cards. The interfaces provided are: Ethernet, 10BaseT, RS-232, and BITS clock inputs. (Wire wrap posts 1.544 meg). 1VU brackets for mid-mounting shipped with this assembly for mid-mounting. This assembly contains a Telcordia CLEI (Common Language Equipment Identifier) label.
Доступно под заказ
CTRL CARD PRI APS The PRI APS Control Card in combination with the I/F CARD PRI APS (90-6345-02) and E1/T1 PRI APS SHELF (90-6344-01) provides N:1 Automatic Protection Switching support for T1/E1 CE Cards on the 36170. Each T1/E1 Card serving as a protection card on the 36170 must be connected to an APS Control Card in the APS Shelf. The APS Control Card controls the relays on APS Interface Cards and allows multiple N:1 protection groups to be supported within the same PRI APS Shelf.
Доступно под заказ
DATA COMMUNICATION PROCESSOR (DCP) CARD The Data Communication Processor card provides for increased CPSS throughput. This card is supported by Generic 1113 or greater. This assembly contains a Telcordia CLEI (Common Language Equipment Identifier) label.
Доступно под заказ
DATA SPOOLING CARD-2 R4.3 This is a UCS card that transfers statistics and accounting data on an external Data Collector, for billing or bulk statistics accumulation. Comes with DB-25 to RJ-34 Ethernet 10Base-T MAU. This card is delivered with R4.3 software.
Доступно под заказ
DB15M - DB37F DTE 3M CABLE
Доступно под заказ
DB25 ALARM CABLE
90-0572-02
DB25 ALARM CABLE
Доступно под заказ
DB78 TO DB78 CABLE (16 COAX) This cable is used to connect the 7470 8 port DS3 CR card to the 8 port 75 Ohm BNC distribution panel.
Доступно под заказ
DC POWER UNIT clei For use in 23 inch DC 8UCS (90-0010-15) or 23 inch DC Switching Shelf (90-0662-06). This power supply is also used in the 3600+ 19 shelf (90-2671-02) and 23 shelf (90-2672-02). Two power supplies can be installed in the 90-0010-15 or 90-0662-06 for redundancy or load sharing. In a 3600+ shelf, power supply redundancy is met in a 2+1 configuration. This assembly contains a Telcordia CLEI (Common Language Equipment Identifier) label.
Доступно под заказ
DC PWR 48VDC UPGR KIT
Доступно под заказ
DC PWR MODULE
90-1723-02
DC PWR MODULE
Доступно под заказ
DC PWR MODULE -48V
90-1723-01
DC PWR MODULE -48V
Доступно под заказ
DCE CABLE 3M/FEMALE V.35 V.35 SUBD26M-M34F DCE CABLE 3M. This cable is for use with the Programmable Serial Interface I/O card.
Доступно под заказ

<< пред   1   ...  13   14   15   16   17   18   19   20   21   22   23    ...   46   след >>

(пусто)
 
Блог / Новости
Голосование